Monday, June 3, 2019
Photochemical Degradation of Pharmaceutics Experiment
Photochemical Degradation of Pharmaceutics ExperimentExperimental methodological psychoanalysisExperimental methodology executed for accomplishment of a project is one of the most important parts of remove, deciding the ultimate outcomes of the canvass. For the present study It aimed at metal doped MCM-41 for the removal of pharmaceutics by then degradation under UV irradiation. The present investigation was therefore designed to avoid discrepancies as much as possible, and to maximize the outcomes.The photochemical degradation of pharmaceutics has become an important index in ecological environment safety evaluation of drugs. To discharge the photodegradation profiles of drugs in the environment, many investigators have focuse on origin photolysis in organic solvents or in a dilute aqueous solution. The present study was based on photo degradation of deuce commonly used pharmaceutics i.e., salts of diclofenac and atorvastatin in several(predicate) solvents. Another perspectiv e of the present study was to deter instante the metal dopped mesoporous silicates materials as catalyst for the photo degradation of pharmaceutics under UV radiations, sun get down and in absence of crystallise.The details of the experimental methodology adopted are spelled out as under3.1 The glassware/ volumetric ApparatusThe proper and appropriately cleaned and calibrated glassware and volumetric apparatus is obligatory for accurate and precise analytical measurements. Thus, high quality pyrex glass-ware was used during the course of experiment. This apparatus was given done wash with detergent solution, diluted HNO3 and finally with distilled piss. alone the glassware used was dried at 100oC in an electric oven before use. All the apparatus like beakers, measuring flasks, pippets and graduated cylinders were calibrated prior to use.3.2 The Reagents deductive reasoning of mesoporous silica, metal dopping on synthesized mesoporous material and degradation studies required va rious reagents. In addition to other parameters, the success of experimental methodology also depended on their virtuousness and quality. So in order to ensure quality analytical grade chemicals which were purchased from Uni-chem (China), E.Merk (Germany), Riedel-deHaen (China) and Sigma Aldrich were used.Sodium silicate, cetyltrimethyl ammonium bromide (CTAB), H2SO4,(NH4)2 Ce(NO3)6, Cu(NO3)2.3H2O and copper acetate were obtained from sigma Aldrich with a crtified purity of 99.9%. In order to avoid any photo degradation, all the reagents were kept in dark.3.3 Equipments/ instruments useda. The following equipments were used for the successful completion of the present study.Magnetic stirrer/ Hot plateOvenShakerMuffle furnaceUV-irradiatorpH meterb Instrument UsedUV- Visible SpectrophotometerThe spectro photometric measurements were performed on a UV ocular double-beam spectrophotometer (U-2800). It operates on the principle of measurement of the intensity of light after passing thr ough a sample (I) and comparing it to the intensity of light before it passes through the sample (Io). The ratio (I/I0 ) is called the transmittance, and is usually expressed as a percentage (%T). The absorbance, A is calculated by the following equationA= log (%T/100)The basic compartment of a spectrophotometer include light source, sample holder, a diffraction grating or monochromator to separate the different vagabondlengths of light, and a detector. The radiation source is often a tungsten filament (300-2500nm) and a deuterium arc lamp, which is continuous over the ultraviolet region (190-400nm). More recently, light emitting diodes (LED) and xenon arc lamps for visible wave length have also been incorporated. The detector is typically a photodiode or CCD (charge couple device detector to enhance the uv spectrophotometer performance). Photodiodes present with monochromators filter the light so that only light of single wavelength reaches the detector. Diffraction gratings with CCDs collect light of different wavelength on different pixels.1og10Io/I= lc= greek letter, epsilonl= length of solution the light passese through(cm)c = concentration of solution (mol dm-3)The expression 1og10Io/I is known as the absorbance of the solution and is measured by the spectrometer.For the present study the UV spectrophotometer was used for determine the degradation of different pharmaceutical products under different conditions. For this purpose the absorbance of diclofenac sodium was recorded at a wavelength of 276 nm and that of atorvastatin was recorded at wavelength of 246 nm.c Bruker alpha ATR spectrophotometerThe Platinum ATR is a single reflection diamond ATR sampling module that is designed to significantly ease analysis. The ergonomic one finger secure mechanism simplifies the sample positioning. The robust diamond crystal allows analyze nearly all kind of liquid and solid samples. For the present study the IR analysis of MCM-41, Cu/MCM-41 and Ce/MCM-41 wasc S DT-Q600 Thermo Gravimetric AnalyserThe TA Instruments SDT-Q600 Simultaneous TGA / DSC provides simultaneous measurement of weight change (TGA) and true differential heat proceed (DSC) on the same sample from ambient to 1,500 C. It features a field-proven horizontal dual beam design with automatic beam growth compensation, and the ability to analyze two TGA samples simultaneously.For the present study the thermogravimetric analysis of mesoporous silicate was3.2 Analytical Methodology3.2.1 conceptualisation of mesoporous silicaFor the preparation of mesoporous silica the method of Taron et.al was used. i In this method the sodium silicate was used as a source of silica and cetyltrimethyl ammonium bromide (CTAB) used as a surfactant. Briefly, a 15.75g part of sodium silicate was dissolved in 45.75g of DDW and steamy for 15 minutes at mode temperature in a poly propylene container (A). A 13.535g of CTAB was separately dissolved in 200 ml of twice distilled water at room temperature to prepare an aqueous solution of CTAB (B). To a stirred solution of precursor (A), the template solution (B) was added drop wise. After the completion of addition, the solution was advertise stirred for about 1h. Subsequently the pH of the contents was maintained at 10.5 by using 11 H2SO4, (6.7ml) which yielded a gel that was further stirred for about 45 minutes. The polypropylene container was then sealed and allowed to age for twenty four hours at room temperature without stirring. The gel thus obtained was filtered, washed with doubly distilled water to get rids of ions present as impurities and dried in an electric oven at 120oC. Thus dried product was allowed to calcine at a heat energy rate of 3oC/min for 6 hours while maintaining a maximum temperature of 550oC. The product obtained after calcinations was mesoporous silica MCM-41, that was used for further experiments.3.2.2 Metal impregnation of mesoporous silicaa) planning of CeO2/MCM-41Li et.al method was adopted for th e synthesis of MCM-41/CeO2.ii This is based on grinding of precursors. In this method, 0.6402 g of (NH4)2Ce(NO3)6 and 0.3g of synthesized MCM-41 were placed in a mortar and ground significantly at room temperature conditions. The obtained solid was calcined at a heating rate of 5oC/min until the maximum temperature obtained 550 C in air for 3 to 4 h to remove the surfactant moleculesiiib) Preparation of copper supported mesoporous silica (Cu/MCM-41)The copper was loaded on the mesoporous support material through wet impregnation of silica. 2g of silica was stirred in 0.025M of 20mL copper acetate for 24 hours at room temperature. The copper impregnated silica was washed with distilled water to remove free copper and acetate ions and then dried at 70oC for 12h. The copper impregnated silica was calcined at 600oC for 4 h to get silica supported copper sample (Cu-MS).ivc) Preparation of Cu-dopped MCM-41 with different percentagesThe MCM-41 mesoporous powder material after drying at 120 oC over night was impregnated with solutions of different concentrations separately under continuous stirring for 12 h at room temperature, and then they were dried at 100oC. The obtained materials were calcined in air from room temperature to 150oC at 5oC/min and held at 150oC for 1 h, and then heated from 150oC to 250oC at the rate of 5oC/min and held at 250oC for 1 h, at last heated from 250oC to 330oC at 5oC/min and held at 330oC for 2 h. By using this procedure, samples containing 5, 10 and 15 wt% Cu-MCM-41 was prepared. v3.2.3 Degradation studiesPreparation of Pharmaceutics StandardsPharmaceutics Stock Solution PreparationA primary standard solution of pharmaceutics with concentration 1000 ppm was prepared by turn 0.1 g of pharmaceutics in 100 mL of solvent. The solution was kept in refrigerator at 4oC prior to use.Pharmaceutics Spiking Solution PreparationThe mediocre standard solutions of pharmaceutics were prepared by diluting 0.5, 0.4. 0.3, 0.2 and 0.1mL of 1000ppm of st ock solution upto 10mL of solvent to prepare 50, 40, 30, 20 and 10 ppm of standards. prepare of lightEffect of timeEffect of metalEffect of metal loading levelsEffect of pHREFERENCESi H. W. Lee , H. J. Cho , J.H. Yim , J. M. Kim , J.K. Jeon , J. M.Sohn , K.S. Yoo , S.S. Kim , Y.K. Park , Removal of Cu(II)-ion over amine-functionalized mesoporous silica materials, Journal of Industrial and Engineering chemistry (17) 504509(2011)ii H. R.Pouretedal, M.Ahmadi, Synthesis, characterization, and photocatalytic activity of MCM-41 and MCM-48 impregnated with CeO2 nanoparticles, journal of International Nano Letters, 210(2012)iii (Li, Y, Yan, B, Functionalized mesoporous SBA-15 with CeF3 Eu3+ nanoparticle by three different methods synthesis, characterization, and photoluminescence. Nanoscal. Res. Lett. 5, 701708 (2010).iv Manish dixit, Manis mishra, P.A.Joshi, D.O.Shah, Study on the catalytic properties of silica supported copper catalysts, journal of procedia engineering, 51, 467-472(2013) .v Ye Wan, Chao Chen, Weiming Xiao, Lijuan Jian, Ning Zhang, Ni/MIL-120 An efficient metalorganic framework catalyst for hydrogenation of benzene to cyclohexane , Microporous and Mesoporous Materials 17, 1 913(2013).
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.